NABL-accredited calibration lab · ISO/IEC 17025 NABL accredited · On-site across India On-site calibration across India
Calibration

How to Choose a NABL Calibration Lab for Your Hospital

A step-by-step guide for hospitals on verifying a NABL calibration lab, reading its scope of accreditation, and checking on-site capability, reference equipment and certificates.

  • By the Shiwi engineering team
  • 6 min read
Blog banner with an ECG trace and the title How to Choose a NABL Calibration Lab for Your Hospital

To choose a NABL calibration lab for your hospital, first confirm the lab’s accreditation is current on the NABL website, then check that its scope of accreditation covers the specific equipment and parameters you need calibrated. After that, look at practical points: whether it can calibrate on site, which reference analysers it uses, what its certificates contain, and whether it can deal with devices that fail.

Many labs describe themselves as “NABL calibration” providers. The accreditation is only meaningful for the work it actually covers, so a few careful checks before you sign a contract will save trouble at your next audit.

What does NABL accreditation mean for a calibration lab?

NABL is the National Accreditation Board for Testing and Calibration Laboratories, a constituent board of the Quality Council of India. According to NABL, it accredits calibration laboratories in accordance with ISO/IEC 17025, the international standard for the competence of testing and calibration laboratories, and carries out third-party assessment of their technical competence. NABL is also a signatory to the mutual recognition arrangements of APAC and of Global Accreditation Cooperation, which took over the work of ILAC from 1 January 2026, which help calibration results be accepted across countries.

In practical terms, a NABL-accredited lab has been independently assessed on its staff competence, methods, reference equipment, measurement traceability, uncertainty estimates and quality system. It is then accredited for a defined scope, not for everything it might offer.

Step 1: Verify the accreditation on the NABL website

Do not rely on a logo on a brochure or a PDF certificate sent by email. Check the lab directly:

  1. Go to the NABL website at nabl-india.org.
  2. Use the “Find an NABL accredited Lab” search on the home page.
  3. Search by the lab’s name or certificate number. The search can also be filtered by standard, parameter and category.
  4. Confirm the lab’s name, address and certificate number match what you were given, and that the accreditation is valid on today’s date.

NABL’s own guidance to customers (see nabl-india.org) is to verify a lab’s validity and authenticity on the NABL website and to ask the lab for its scope of accreditation.

Step 2: Read the scope of accreditation

The scope is the most important document in this process. It lists the parameters, measurement ranges and uncertainties for which the lab is accredited. A lab may be accredited for some parameters and not others.

When you read the scope, check:

  • Does it cover medical equipment? Look for the parameters relevant to your devices, such as those measured on patient monitors, defibrillators, infusion pumps, ventilators and electrosurgical units, and for electrical safety.
  • Do the ranges fit your equipment? A range that stops short of what your device delivers will not cover the full calibration.
  • Does it include calibration at the customer’s site? If you want on-site calibration, ask the lab to show you that its accreditation covers work carried out at your premises, not only in its own laboratory.
  • Are the uncertainties suitable? The lab’s uncertainty should be small enough relative to the tolerance of your device to give a meaningful pass or fail result.

If a lab cannot show you the scope, or the scope does not include the work you need, treat any certificate for that work as non-accredited.

Step 3: Ask practical questions about the service

Accreditation tells you the lab is competent. It does not tell you whether the lab can serve your hospital well. These questions help with that.

Question to ask Why it matters
Can you calibrate on site at our location? Avoids taking ICU and OT equipment out of service and the risk of damage in transit
Which reference analysers and simulators do you use? Shows whether they have proper biomedical test equipment for each device type
Is the reference equipment itself calibrated, and is it traceable? Your results are only as reliable as the reference behind them
Do you issue one certificate per instrument? Auditors expect device-level evidence, not a department summary
Do you include electrical safety testing? Leakage current, earth and insulation checks are part of a complete visit
What happens if a device fails? A lab that can also repair saves you arranging a separate engineer
Can you cover all our equipment in one visit? Fewer visits mean less disruption and simpler records
Can I see a sample certificate? Lets you check the format before you commit

Step 4: Check a sample calibration certificate

A good certificate should let anyone, including an auditor, understand what was tested and how. Look for:

  • The lab’s name, address and NABL certificate number
  • The NABL symbol for the accredited parameters. NABL’s guidance is to check for the symbol and to ask the reason if it is missing from a report that should carry it.
  • Device description, make, model, serial number and your asset ID
  • Date and place of calibration
  • Reference equipment used and its traceability
  • Results for each test point, acceptance limits and measurement uncertainty
  • A clear pass or fail statement
  • Signatures of the engineer and the authorised signatory

Our guide on medical equipment calibration explains what each of these means in practice.

Warning signs to look out for

  • The lab’s name does not appear in the NABL directory, or the certificate has expired.
  • The lab says it is “NABL” but will not share its scope.
  • Certificates for parameters outside the scope still carry the NABL symbol.
  • One certificate is issued for a whole department or a batch of devices.
  • No electrical safety results are provided for mains-powered equipment.
  • The engineer arrives without dedicated analysers for the devices being tested.

Does location matter when choosing a lab?

Less than it once did. A lab with an on-site calibration capability can bring its reference equipment to you, so the lab’s city matters less than whether it can reach your hospital, plan the visit around your clinical schedule and cover every device in one trip. This is especially relevant for hospitals and clinics outside the major cities, which may have fewer local options.

This article is general guidance. Calibration and electrical safety testing should follow the manufacturer’s service manual and be done by qualified biomedical engineers.

Why hospitals work with Shiwi

Shiwi Enterprises is a NABL-accredited calibration lab (ISO/IEC 17025) in Jaipur. We calibrate on site across India, including hospitals and clinics in small towns and villages, and have completed more than 500 calibration projects. Our engineers test each device against calibrated reference analysers, check performance parameters and electrical safety, and issue a calibration certificate for every instrument, ready for NABH and internal audits. Because the same team also handles repair and preventive maintenance, a device that fails calibration does not have to wait for a separate service provider. You can read more about our NABL lab or see the equipment we calibrate.

If you are comparing labs because of an upcoming audit, our NABH calibration requirements checklist and our explainer on NABL vs non-NABL calibration may also help.

Talk to us about your equipment

Send us your equipment list and location, and we will tell you what we can calibrate on site and how we would plan the visit. Request a quote or contact our team.

Frequently asked questions

How do I check if a calibration lab is NABL accredited?

Go to nabl-india.org, use the “Find an NABL accredited Lab” search on the home page, then search by the lab's name or certificate number and confirm the accreditation is valid.

What is a scope of accreditation?

It is the document that lists the specific parameters, ranges and measurement uncertainties for which a lab is accredited. Work outside the scope is not covered by the accreditation.

What standard are NABL calibration labs accredited against?

NABL accredits calibration laboratories in accordance with ISO/IEC 17025.

Can a NABL lab calibrate equipment at my hospital?

Many can, but ask the lab to show that its accreditation covers calibration carried out at the customer's site, not only in its own laboratory.

Request a calibration quote

List your equipment with make, model and quantity, and tell us your city. We reply with a quote and a visit plan.

    Planning calibration before your next audit?

    Send us your equipment list and city. We will reply with a quote and a visit schedule.

    Scroll to Top